Драйвер Intel EFI Firmware 02.06.0002 Intel Система P4208IP сервера

НаименованиеEFI Firmware 02.06.0002 Intel Система P4208IP сервера
Дата добавления11.02.2016
Описание

This update package includes the following system software updates:

- System BIOS - 02.06.0002
- ME Firmware - 02.01.07.328
- BMC Firmware - 01.25.9398
- FRUSDR - 1.12

This download is valid for the products listed below:

- Intel Server Board S2600IP4
- Intel Workstation Board W2600CR2
- Intel Workstation System P4304CR2LFKN
- Intel Workstation System P4304CR2LFJN
- Intel Workstation System P4304CR2LFGN
- Intel Server System R2224IP4LHPC
- Intel Server System R2216IP4LHPC
- Intel Server System R2208IP4LHPN
- Intel Server System R2312IP4LHPC
- Intel Server System R2308IP4LHPR
- Intel Server System R2304IP4LHPN
- Intel Server System P4224IP4LHKC
- Intel Server System P4224IP4LHJC
- Intel Server System P4216IP4LHKC
- Intel Server System P4208IP4LHKC
- Intel Server System P4216IP4LHJC
- Intel Server System P4208IP4LHJC
- Intel Server System P4216IP4LHGC
- Intel Server System P4208IP4LHGC
- Intel Server System P4308IP4LHKC
- Intel Server System P4308IP4LHJC
- Intel Server System P4308IP4LHGC
- Intel Server System R2208IP4LHPC
- Intel Server System R2308IP4LHPC
- Intel Server System P4XXXIP4LXXC
- Intel Server Board S2600IP4L
- Intel Workstation Board W2600CR2L
- Intel Server System P4308IP4LHJCL
- Intel Workstation System P4304CR2LFJNL

Standard Update Procedure from the embedded EFI Shell

- Unzip the contents of the update package and copy all files to a folder on a USB flash drive
- Insert the USB flash drive to any available USB port on the server system to be updated
- Boot the Server to the EFI shell. This can be accessed via the <F2> BIOS setup utility during POST.
- Run the command "map -r" in the EFI shell to mount the USB flash drive
- Run the command "fs0:" to change folders to the USB flash drive. The USB flash drive
may also mount to fs1: depending on other installed devices. The number of "fs#" is
dependent on the result of command "map -r"
- Change folders to the folder storing the update package files
- Run the command "Startup.nsh" to start updating all the firmware and BIOS updates
- Warning: Do NOT reboot or remove power from your system during the update process.
Doing so may render your system inoperable. !!

Verifying updates
- Reboot the system
- During POST, hit the <F2> Key when prompted to access the BIOS Setup Utility
- Hit the F9 key to load BIOS Defaults
- At the MAIN menu verify the BIOS revision is correct
- Move cursor to the SERVER MANAGEMENT Menu
- Move cursor down to the SYSTEM INFORMATION Option and hit Enter
- Verify the BMC Firmware revision is correct
- Verify the SDR revision is correct
- Verify the ME Firmware revision is correct
- Hit the F10 Key to save changes and Exit
- The System Software Update is Complete.

Alternate Update Procedure: Individual Firmware Update Procedure

If you want to update firmware components individually, like BMC/BIOS/ME/FRUSDR, do NOT run the "STARTUP.NSH" file described in the Standard Update Procedure above. Instead, run the individual .NSH script file for each update included in the update package files.

Update BMC Firmware
1) Boot the system to the EFI shell and go to root folder
2) At the shell prompt, run "UpdateBMC.nsh" to start BMC Firmware update
3) When complete, go to the BIOS update section described below, or power off the system and cycle AC power before continuing.

Update System BIOS
1) Boot the system to the EFI shell and go to root folder
2) At the shell prompt, run "UpdateBIOS.nsh" to start BIOS update
3) When complete, reboot the system and enter BIOS Setup by pressing the F2 Key during POST
4) Verify the BIOS string on main BIOS menu
5) Press F9 to load defaults and press F10 to save and reset the system
6) Go to the ME firmware update section described below. The BIOS update is complete. Either reboot the server or go to the ME firmware Update section described below.

Update ME Firmware
1) Boot the system to the EFI shell and go to root folder
2) At the shell prompt, run "UpdateME.nsh" to start ME firmware update
3) When complete, go to the FRUSDR update section described below, or power off the system and cycle AC power before continuing.

Update FRUSDR
1) Boot the system to the EFI shell and go to root folder
2) At the EFI command prompt, run "UpdateFRUSDR.nsh" to start FRUSDR update
3) Answer questions and enter desired information when prompted.
4) When com

Имя файлаS2600IP_W2600CR_EFI_B
Поддерживаемые ОСплатформонезависимое
Размер27.6 МБ
Поддерживаемые устройстваНе задан
Количество скачиваний0
Вы можете скачать драйвер Intel EFI Firmware 02.06.0002 Intel Система P4208IP сервера с сайта производителя нажав на кнопку "Скачать".