Драйвер Intel Intel S2600WP Серверная плата UEFI Firmware 2.06.0002

НаименованиеIntel S2600WP Серверная плата UEFI Firmware 2.06.0002
Дата добавления28.01.2016
Описание

Versions:

- BIOS: 02.06.0002
- ME: 02.01.07.328
- BMC: 01.25.9398
- FRUSDR: 1.09

BIOS R02.06.0002 Changes:

NOTICE: Due to security requirements, downgrade to previous revisions in normal mode is NOT supported. Please use the BIOS Recovery procedure instead.

- Fixed:The EFI script “Variable_reclaim.nsh” cannot complete successful and the BIOS Error Manager screen will show "A0A8" memory update failure error.
- Fixed:POST screen and BIOS setup screen will shows different BIOS version under recovery mode.
- Fixed: Victor Sokolov- Removable RAID Controller .
- Fixed: Change Boot Order with SYSCFG in S2600CO2
- Fixed: "Melock" fix.
- Fixed: (X) BIOS 2.04 help screen text typos.
- Fixed: Romley Security issue.
- Fixed: The link speed of RS3WC080 storage card only report to Gen2 on BIOS R02.04.0002 with SNB CPU.
- Fixed: UEFI Optimized Boot acknowledges F2 Setup to start, but boots Windows instead.

ME 2.01.07.328 Changes:

- Fixed: Platform is not able to power on properly after being shut down by NM Policy
- Fixed: Global platform power consumption reported by NM Statistics in S5 is incorrect
- Fixed: OOB (out-of-band) stress test by issuing the wrong username may cause connection to be unavailable
- Fixed: Shutdown action can be interrupted by cold reset when volatile NM policy is in use

BMC 01.25.9398 Changes:

- BMC change to ensure the system remains off after an over current event until the system has been AC power cycled.
- Add a new support for only TLS1.2 protocol(both for stunnel and openssl).
- Disable stunnel for ihc.
- The www section as location is changed from 00c00000 to 00c20000.
- Update openssl to 1.0.2d.

FRUSDR 1.09 Changes:

- Add SDR 'PSU0 Status' and 'PSU1 Status'.

Update BMC Firmware

1) Boot the system to the EFI shell and go to root folder
2) At the shell prompt, run "UpdateBMC.nsh" to start BMC Firmware update
3) When complete, go to the BIOS update section described below, or power off the system and cycle AC power before continuing.

Update System BIOS

1) Boot the system to the EFI shell and go to root folder
2) At the shell prompt, run "UpdateBIOS.nsh" to start BIOS update
3) When complete, reboot the system and enter BIOS Setup by pressing the F2 Key during POST
4) Verify the BIOS string on main BIOS menu
5) Press F9 to load defaults and press F10 to save and reset the system
6) Go to the ME firmware update section described below
7) The BIOS update is complete. Either reboot the server or go to the ME firmware Update section described below.

Update ME Firmware

1) Boot the system to the EFI shell and go to root folder
2) At the shell prompt, run "UpdateME.nsh" to start ME firmware update
3) When complete, go to the FRUSDR update section described below, or power off the system and cycle AC power before continuing.

Update FRUSDR

1) Boot the system to the EFI shell and go to root folder
2) At the EFI command prompt, run "UpdateFRUSDR.nsh" to start FRUSDR update
3) Answer questions and enter desired information when prompted.
4) When complete, reboot the system by front control panel

Verifying updates

- Reboot the server
- During POST, hit the <F2> Key when prompted to access the BIOS Setup Utility
- Hit the F9 key to load BIOS Defaults
- At the MAIN menu verify the BIOS revision is correct
- Move cursor to the SERVER MANAGEMENT Menu
- Move cursor down to the SYSTEM INFORMATION Option and hit Enter
- Verify the BMC Firmware revision is correct
- Verify the SDR revision is correct
- Verify the ME Firmware revision is correct
- Hit the F10 Key to save changes and Exit
- The System Software Update is Complete.

This download is valid for the products listed below:

- Intel Server Board S2600WP
- Intel Server Board S2600WPQ
- Intel Server System H2312WPJR
- Intel Server System H2312WPQJR
- Intel Server System H2312WPKR
- Intel Server System H2312WPQKR
- Intel Server System H2216WPJR
- Intel Server System H2216WPQJR
- Intel Server System H2216WPKR
- Intel Server System H2216WPQKR
- Intel Server Board S2600WPF
- Intel Server System H2312WPFJR
- Intel Server System H2216WPFJR
- Intel Server System H2312WPFKR
- Intel Server System H2216WPFKR

About Firmware Updates:

Applying a newer firmware version

Имя файлаS2600WP_EFI_BIOS02060002_ME020
Поддерживаемые ОСОС Независимый
Размер27.7 МБ
Поддерживаемые устройстваНе задан
Количество скачиваний0
Вы можете скачать драйвер Intel Intel S2600WP Серверная плата UEFI Firmware 2.06.0002 с сайта производителя нажав на кнопку "Скачать".