This download provides support for Intel HM87, C232, C236, and C600 chipsets on both AHCI Capable SATA Controller and SATA/SAS Capable Controller in Intel Embedded Server RAID Technology 2 (ESRT2) mode. Defects Fixes:- (Resolved) - WG: Patrol Read GET in SWR does not fetch the latest data, issue related to events - (Resolved) - RAID 1 VD is offline with 4K drives when auto Resume Disabled in Ctrl Proprieties - (Closed) - Cannot update WD FW in ESRT2 using CMDTool2 8.07.16 with ESRT2 driver version 15.04.2013.1016 - (Closed) - Software RAID buffer IO error observed when initialization started on VD - (Closed) - SWR controller is not detected even after providing driver during OS installation - (Closed) - Display wrong controller name with one of device ID (GreenGem2 ID) - (Resolved) - Hundreds of entries are filling up dmesg with message: unable to retrieve proper sense data. For particular SATA DVD - (Closed) - blinking amber in HD slot 2 and 3 after wake up from Windows 7 with ESRT2 RAID
Requested Enhancements:- (Closed) - Enabling R5 in uEFI mode by default for Intel Greenlow server - (Implemented) - Enabled RAID 5 key detection feature in uEFI - (Implemented) - Add PNP ID for OEM SunrizePoint system - (Implemented) - Add PCI IDs for FTS skylake server - (Implemented) - Add PNP ID for Intel "Greenlow Silver Pass" - (Implemented) - RAID key detection changes based on new Greenlow PCH GPIO changes - (Implemented) - PNP ids for NEC Grantley and Greenlow Servers
CSET Activities:- (Port_Complete) - SWR: Storcli: Able to delete the OS VD without force. - (Active) - Software RAID buffer IO error observed when initialization started on VD
Base CM Activities:- (Active) - API changes to support write verify during cache flush - (Completed) - 1.50 Pre-Alpha Release check-ins - (Completed) - add comment in device id list. - (Completed) - Script change to accommodate new Driver signature. - (Completed) - 1.50 RC build check-in - (Completed) - 1.50 -Driver Version change [0901-2015] - (Completed) - 1.50 win 10 release check-in - (Completed) - 1.43 point release version check in. - (Active) - Changing the uEFI TimeStamp from 14.x to 15.x - (Completed) - controller type wrongly checked in as PCI-X instead of PCI-E - (Completed) - 1.50 0915 release checkins - (Completed) - 1.50 test build check ins - (Completed) - 1.50 beta release check-in
This download is valid for the products listed below:- Intel Server Board S3000AH - Intel Server Board S5000VCL - Intel Server Board S3000PT - Intel Server System SR2520SAFR - Intel Server System S7000FC4UR - Intel Server Board S5400SF - Intel Server Board S5520UR - Intel Server Board S5520HC - Intel Workstation Board S5520SC - Intel Server Board S5500BC - Intel Server Board S5500WB - Intel Server Board S5500HCV - Intel Server System SR2625URLX - Intel Server System SR2600URBRP - Intel Server Board S5500HV - Intel Server System SR2612UR - Intel Server Board S5000VSA4DIMMR - Intel Server Board S5000VSASASR - Intel Server Board BSHBBL - Intel Server Board S5000XSLSATAR - Intel Server Board S3420GPLC - Intel Server Board S3200SHV - Intel Server Board S5000VSASATAR - Intel Server Board S3210SHLX - Intel Server Board S5000PSLROMBR - Intel Workstation Board S5000XVNSATAR - Intel Server Board S5500WB12V - Intel Server Board S5000PALR - Intel Server Board S5000VSASCSIR - Intel Workstation Board S5000XVNSASR - Intel Server Board S3210SHLC - Intel Server Board S5000PSLSASR - Intel Server Board S3420GPLX - Intel Server Board S5000PSLSATAR - Intel Server Board S5000PAL - Intel Server Board S5000PSLSATA - Intel Workstation Board S5000XVN - Intel Server Board S5000XALR - Intel Server System SR1630GP - Intel Server System SR1630HGP - Intel Server System SR1630BC - Intel Server System SC5650HCBRP - Intel Server System SR1600UR - Intel Server System SR1625UR - Intel Server Board S3420GPV - Intel Server Board S3420GPRX - Intel Server System SR2520SAXR - Intel Server System SR2520SAXSR - Intel Server System SR1630BCR - Intel Server System SC5650BCDPR - Intel Server System SC5650HCBRPR - Intel Server System SR2625URLXR - Intel Server System SR2625URLXT - Intel Server System SR2625URBRP - Intel Server System SR2625URBRPR - Intel Server System SR1600URR - Intel Server System SR1600URHS - Intel Server System SR1600URHSR - Intel Server System SR1625URR - Intel S |